Skip to content

NFPA 110 Compliance Services for Critical Facilities

Infrastructure of a modern hyperscale data center aisle edited
Powering Industries for 50+ Years

NFPA 110 Compliance Services for Critical Facilities

Protecting Critical Operations With Expert NFPA 110 Generator Compliance

Whether your business is a hospital, data center, municipal building, or industrial plant, the reliability of your emergency power system is more than operational, it’s a legal and ethical requirement. The NFPA 110 Standard from the National Fire Protection Association sets the benchmark for the installation, maintenance, and testing of Emergency Power Supply Systems (EPSS). Achieving and maintaining NFPA 110 compliance requires ongoing diligence.

Non-compliance isn’t just risky, it’s costly. It can result in failed regulatory inspections, fines, or worst of all, the failure of life-safety systems during a power outage.

At Generator Source, we deliver NFPA 110 compliance services for mission-critical facilities across the United States, including in Colorado, Florida, Texas, Wyoming, and Georgia. Our EGSA-certified technicians ensure your EPSS is compliant on paper and reliable in practice.

The High Stakes of Non-Compliance

Healthcare Facilities

hospital

Compliance with NFPA 110 is essential for hospitals and medical centers. Failures in generator performance can threaten lives, particularly for patients on ventilators or surgical equipment. The Joint Commission and CMS enforce strict rules, and non-compliance can jeopardize accreditation and funding.

Data Centers

Infrastructure of a modern hyperscale data center aisle edited scaled

In data centers, uptime is currency. A power interruption of even a few seconds can corrupt data, violate Service Level Agreements (SLAs), and cause severe financial and reputational harm. NFPA 110 compliance supports the 99.999% uptime standard demanded by global businesses.

Industrial and Manufacturing Facilities

Artboard 3

An unexpected power outage can shut down operations, destroy in-process product, and create hazardous conditions for employees. A compliant EPSS prevents downtime and protects your bottom line.

Municipal and Government Buildings

Water Pumping Station Municipality Utility edited

From 911 call centers to water treatment plants, the EPSS ensures continuity of public safety operations. Failure to comply can result in breakdowns of emergency response and disruption of critical services.

Our NFPA 110 Compliance Services


1. On-Site EPSS Audits and Gap Analysis

Our technicians perform a comprehensive on-site assessment of your emergency power systems:

  • Physical Equipment Inspection: Generator sets, fuel delivery, cooling, exhaust, and battery systems
  • ATS Functionality Check: Verifying correct transfer logic and safe operation
  • Logbook and Documentation Review: Ensuring your testing logs, service records, and fuel reports are complete and audit-ready
  • Gap Analysis Report: Identifies issues, missing documentation, and outdated components, plus a prioritized roadmap for remediation

2. Customized Preventative Maintenance Plans

We build facility-specific PM programs aligned with Level 1 or Level 2 system requirements under NFPA 110:

  • Engine oil, coolant, and filter changes
  • Fuel system and fuel quality inspection
  • Battery charger testing and voltage verification
  • Cooling system analysis
  • Control wiring and electrical connection checks

3. EPSS Testing Services (NFPA 110-Mandated)

We bring portable resistive and reactive load banks on-site, minimizing disruption and maximizing compliance. We conduct all NFPA 110 required inspections and testing with certified equipment:

  • Weekly Visual Checks: Ensures the system is in ready condition with no alarms
  • Monthly No-Load Exercises: 30-minute run to verify operability and fluid circulation
  • Quarterly and Semi-Annual Load Tests: Intermediate validation of system health
  • Annual and Triennial Load Bank Testing: Full-load simulations to validate generator capacity and performance under real stress

4. Professional Compliance Documentation

After every visit or service, you receive:

  • Detailed service logs
  • Test results and inspection findings
  • Technician name and certification
  • Noted deficiencies and corrective actions taken
Read more about NFPA 110 Generator Requirements

Our Compliance Process


Generators for Critical Facilities
Step 1: Initial Consultation – We review your facility’s risk level, power requirements, and any previous inspection challenges.
Step 2: EPSS Audit and Gap Analysis – We assess every system element and provide your team with a comprehensive report and compliance roadmap.
Step 3: Plan Proposal – We present a step-by-step proposal to bring your facility into full NFPA 110 compliance, including PM schedules and testing calendars.
Step 4: Execution and Documentation – Our technicians implement the plan and provide full compliance reporting for your generator logbook and EPSS documentation.
Step 5: Ongoing Support – We offer year-round maintenance contracts, 24/7 emergency service, and support for re-inspections or upgrades as codes evolve.

Areas We Serve

Generator Source provides NFPA 110 compliance services for critical facilities throughout:

  • Colorado (Denver, Boulder, Colorado Springs, Fort Collins)
  • Florida (Jacksonville, Pensacola, Orlando, Tampa)
  • Texas (Austin, San Antonio, Houston, Dallas)
  • Southern Georgia
  • Southern Wyoming
Screenshot 2025 02 25 105016
Driven by Quality, Powered by Service
499148112 1058832396354973 8995944426111250582 n
491377156 1038337931737753 3817666418240852307 n edited
Reflection Ad Pics edited scaled
Ad Pic Part 2 4 edited scaled
Diesel Generator Engine Advantages of Using Diesel Generators Today Kohler Install 1 edited

Don’t Wait for an Audit to Find a Problem

Let Generator Source help you get compliant and stay compliant. Contact us now to schedule a site visit or learn more about our NFPA 110 Compliance Assessments.

👉 Request Your Compliance Audit

Still have questions or looking for more information?

Generator Source specializes in low-hour, used, new, and surplus generator sets. We have a wide variety of generator sizes and models to fit any project. We are not a broker, we own what we sell.
Call us today (877-866-6895) or click Contact Us to be connected with one of our experienced sales reps. 
We have 350+ generators in stock and ready to ship!

Still have questions or looking for more information?