Water Separator Maintenance

Water Separator Maintenance

Generator water separator removing moisture from diesel fuel
Water separators remove water from diesel fuel before it reaches lift pump filters and injection system. As water builds up it increases corrosion and supports microbial growth.

System Function

The water separator removes water from diesel fuel before it reaches the lift pump, filters and injection system. It collects water in a bowl or drain point so it can be removed during routine service. As water builds up it increases corrosion and can support microbial growth in the tank and fuel circuit.

  • Water Removal: Separator uses density difference between water and diesel allowing water to settle in collection bowl where it can be drained preventing water from reaching injection components.
  • Contamination Prevention: By removing water before it enters fuel system the separator prevents corrosion of injection components and eliminates moisture that supports biological growth in fuel.

Moisture carried downstream creates blockages and corrosion, contributes to premature fuel component failure, and can cause rough running or surging under load. Even if engine starts fine in cold weather trapped water can freeze and restrict fuel flow leading to intermittent no-start problems.

Water separator service video

Video Thumbnail

Maintenance Schedule

How often should it be drained?

How often should element be replaced?

Water separators are serviced by draining the bowl, checking for water and debris, and confirming seal condition every quarter during PM1 inspections—not just left until filter change. Separator element replaced annually during PM2 service or when water accumulation becomes excessive.

Environmental Considerations: Generators with outdoor above-ground fuel storage experience more condensation requiring frequent water separator draining. High humidity environments accelerate water accumulation in fuel. Biodiesel fuels naturally absorb more moisture requiring more frequent separator service. Generators in cold climates risk water freezing in separator during winter operation.

How you can tell it is acting up

  • Water in Separator Bowl: Visible water accumulation in collection bowl indicating condensation in fuel system or contaminated fuel delivery.
  • Fuel Filter Plugging: Frequent fuel filter replacement needed suggesting water passing separator and supporting microbial growth.
  • Hard Starting in Cold Weather: Extended cranking or no-start conditions in freezing temperatures indicating frozen water in separator restricting fuel flow.
  • Rough Running or Surging: Engine runs unevenly under load suggesting water contamination affecting combustion or causing injector problems.
  • Corrosion in Fuel System: Rust or corrosion visible in fuel filters or lines revealing moisture presence in fuel circuit.
Technician draining water from fuel separator bowl
Regular separator draining removes accumulated water before it reaches injection system. Water contamination causes injector corrosion and supports microbial growth that plugs filters.

Most asked question

“My separator bowl is clear with no visible water—does it still need draining?”

Yes. Drain separator regardless of visible water accumulation. Small amounts of water present may not be visible in bowl especially if mixed with fuel. Water naturally accumulates in fuel systems from condensation as temperature cycles throughout day and seasons. Even generators burning clean fuel from quality suppliers experience moisture accumulation. Draining separator quarterly removes accumulated water before it reaches critical injection components. Water in injection system causes rapid corrosion of injector nozzles and pump components requiring expensive replacement. Water also supports microbial growth diesel bug that creates black slime plugging filters and corroding tank and fuel lines. Regular separator draining is essential preventive maintenance costing pennies but preventing thousands in fuel system repairs.

Frequently Asked Questions

What causes water accumulation in fuel systems?

Condensation is primary source. Temperature cycling causes moisture in tank air space to condense on cool tank walls dripping into fuel. Humid climates accelerate condensation formation. Underground tanks below water table may have groundwater intrusion through damaged seals. Biodiesel fuels naturally absorb moisture from air. Poor quality fuel from suppliers. Rainwater entering through damaged tank caps or vents. Most generators experience some water accumulation regardless of fuel source making regular separator draining essential.

How much water is normal to find in separator?

Small amounts typically few ounces per quarterly drain are normal from condensation. Large amounts pint or more suggest excessive condensation from large temperature swings contaminated fuel delivery or possible tank intrusion. Consistently high water accumulation requires investigation of fuel storage conditions tank integrity and fuel source quality. Biodiesel systems normally show more water than conventional diesel. Any water accumulation must be removed as even small amounts cause corrosion and support microbial growth.

Can I eliminate water separator if fuel is clean?

No. Water separator is essential component regardless of fuel quality. All diesel fuel contains some dissolved moisture. Temperature changes cause moisture to come out of solution settling in lowest points of fuel system. Even premium fuel from major suppliers contains trace moisture. Separator provides critical first line defense removing water before it reaches expensive injection components. Eliminating separator voids equipment warranties and dramatically increases risk of fuel system damage. Water separator maintenance is inexpensive insurance against expensive fuel system repairs.

Why does water damage fuel injection systems?

Water causes rapid corrosion of precision injection components. Injector nozzles are manufactured to extremely tight tolerances measured in microns. Corrosion from moisture degrades these precision surfaces causing poor spray patterns and incomplete combustion. Water contamination supports bacteria and fungus growth creating acidic byproducts that accelerate corrosion. Water freezes in cold weather restricting or blocking fuel passages. Water does not lubricate like diesel causing accelerated wear in injection pumps. High pressure injection systems are particularly vulnerable as water contamination causes catastrophic pump and injector failure requiring complete system replacement.

Schedule Service

Generator Source services every make and model of commercial and industrial generators from 20kW to 4000kW. Our EGSA-certified technicians bring 50+ years of experience, and we are the largest reseller of new and used commercial generators in the country.

Call 877-866-6895 to speak with a specialist today!

    [hidden select* first_as_label "Generator Service" "Purchase a Generator" "Rent a Generator" "Sell a Generator" "Other"]


    [hidden ip-address default:"[_remote_ip]

    "]


    Still have questions or looking for more information?

    Our Techs are EGSA Certified

    Our certified EGSA technicians deliver exceptional, hands-on expertise that our customers rely on. 

    EGSA Logo Water Separator Maintenance
    Maintenance Item
    31 Point Inspection Items / PM1
    Air Inlet System & Air Filter
    Alternator
    Barrel Insulation
    Batteries
    Battery Charger
    Bearing(s)
    Belts, Hoses & Connections
    Block Heater
    Breaker(s)
    Collect Oil & Coolant Samples
    Coolant & Coolant Filter(s)
    Crankcase Breather(s)
    Exhaust Manifold
    Fan and Fan Drive
    Fuel Filters – Prim/Sec
    Fuel Lines & Connections
    Fuel Tank & Rack
    Gauges
    Governor and controls
    Jacket Water Heater
    Oil & Oil Filter(s)
    Radiator
    Remote Annunciators/Alarms
    Safety Controls
    Starter
    Turbocharger(s)
    Valves and Valve Rotators
    Vibration Isolators
    Voltage
    Water Pump
    Water Separator

    We Service All Major Brands Including

    Cummins Commercial Generators logo
    rehlko Kohler Commercial Generators logo
    Caterpillar Commercial Generators logo
    Generac Commercial Generators logo
    Detroit Generators
    HiPower Commercial Generators logo
    multiquip logo png Water Separator Maintenance
    images Water Separator Maintenance
    Doosan Commercial Generators logo
    mtu logo Water Separator Maintenance
    Volvo commercial generators logo
    baldor commercial generators logo