        Preventative Maintenance 1 (PM1)
        The Industry Standard 31 Point Inspection

        Every quarter,each plan starts with a Preventative Maintenance 1 (PM1) inspection of all 31 critical components, selected from decades of field experience and manufacturer recommendations, so nothing gets overlooked and you get a complete picture of your generator’s health.

        Generator Source 31 Point Certified Inspection Process

        31 Inspection Items & Service Videos

        Maintenance Item PM 1 PM 2 PM 3 Load Bank Test
        Air Inlet System & Air Filters – ๐ŸŽฅโœ”โœ”โœ”
        Alternator – ๐ŸŽฅโœ”โœ”โœ”
        Barrel Insulation – ๐ŸŽฅโœ”โœ”โœ”
        Batteries – ๐ŸŽฅโœ”โœ”โœ”
        Battery Charger – ๐ŸŽฅโœ”โœ”โœ”
        Bearings – ๐ŸŽฅโœ”โœ”โœ”
        Block Heater – ๐ŸŽฅโœ”โœ”โœ”
        Breakers – ๐ŸŽฅโœ”โœ”โœ”
        Collect Oil & Coolant Samples – ๐ŸŽฅโœ”โœ”โœ”
        Controller – ๐ŸŽฅโœ”โœ”โœ”
        Coolant & Coolant Filters – ๐ŸŽฅโœ”โœ”โœ”
        Crankcase Breather(s) – ๐ŸŽฅโœ”โœ”โœ”
        Engine Oil & Oil Filters – ๐ŸŽฅโœ”โœ”โœ”
        Exhaust Manifold – ๐ŸŽฅโœ”โœ”โœ”
        Fan and Fan Drive – ๐ŸŽฅโœ”โœ”โœ”
        Fuel Filters โ€“ Primary / Secondary – ๐ŸŽฅโœ”โœ”โœ”
        Fuel Lines – ๐ŸŽฅโœ”โœ”โœ”
        Fuel Tank – ๐ŸŽฅโœ”โœ”โœ”
        Gauges – ๐ŸŽฅโœ”โœ”โœ”
        Governor – ๐ŸŽฅโœ”โœ”โœ”
        Hoses & Connections – ๐ŸŽฅโœ”โœ”โœ”
        Jacket Water Heater – ๐ŸŽฅโœ”โœ”โœ”
        Radiator – ๐ŸŽฅโœ”โœ”โœ”
        Remote Annunciators & Alarms – ๐ŸŽฅโœ”โœ”โœ”
        Safety Controls – ๐ŸŽฅโœ”โœ”โœ”
        Starter – ๐ŸŽฅโœ”โœ”โœ”
        Turbocharger(s) – ๐ŸŽฅโœ”โœ”โœ”
        Vibration Isolators – ๐ŸŽฅโœ”โœ”โœ”
        Voltage – ๐ŸŽฅโœ”โœ”โœ”
        Water Pump – ๐ŸŽฅโœ”โœ”โœ”
        Water Separator – ๐ŸŽฅโœ”โœ”โœ”
        Additional Service Items
        Change Oil โœ”โœ”
        Change Filters (Oil, Coolant, Fuel, Air) โœ”โœ”
        Change Coolant โœ”
        Change Rubber Hoses & Belts โœ”
        Change Thermostats & Gaskets โœ”
        Collect Fuel Samples Upon Request Upon Request Upon Request
        Transfer Test Upon Request Upon Request Upon Request
        Visual ATS Inspection Upon Request Upon Request Upon Request
        Change Batteries Upon Request Upon Request Upon Request
        Load Bank Test
        Accurate Temperature Gauge Test โœ”
        Auto Start Test & Tag Verifications โœ”
        Check Temperature with Heat Gun โœ”
        Coolant Leaks โœ”
        Engine Alternator Test โœ”
        Full Rating Tests โœ”
        Gauge Adjustment Tests โœ”
        Gauge Compliance Tests โœ”
        Oil Leaks โœ”
        Pre-Alarm Verification โœ”
        Shut Down Verification โœ”

        Preventative Maintenance 2 (PM2)
        PM1 + Fluids, Filters & Load Bank

        A PM2 service includes everything a PM1 does +:

        • A load bank test that applies a controlled load at 25%, 50%, 75%, and 80% to verify capability, stability, and cooling
        • Oil change
        • Oil, air, and coolant filter replacement

        2MW Caterpillar Load Bank Test Highlights

        Video Thumbnail

        Preventative Maintenance 3 (PM3)
        PM1 + PM2 + Major Wear Replacements

        A PM3 service includes everything a PM1 & PM2 does +:

        • Coolant flush
        • Cooling-system hose replacement
        • Sealing gasket replacement
        • Thermostat replacement

        Generator Source Service

        Video Thumbnail

        Still have questions or looking for more information?

        Generator Source specializes in low-hour, used, new, and surplus generator sets. We have a wide variety of generator sizes and models to fit any project. We are not a broker, we own what we sell.
        Call us today (877-866-6895) or click Contact Us to be connected with one of our experienced sales reps. 
        We have 350+ generators in stock and ready to ship!

        Still have questions or looking for more information?

        Generator Service FAQ

        Generator Service FAQ

        Got a question about generator maintenance? Our Service FAQs page covers it. Find clear answers on preventive maintenance intervals, load bank testing, fuel polishing, wet stacking, ATS issues, and NFPA 110 compliance. Written by the technicians who actually service generators in the field every day.

        Custom power solutions, engineered to spec. ATS installation, control panel upgrades, frequency conversions, voltage changes, custom fabrication, paralleling, load bank testing, and oil analysis โ€” all backed by expertise across Deep Sea, Woodward, Caterpillar EMCP, and Cummins Power Command. Tell us what you need.

        Kohler 2250kW Generator with MTU Engine becoming enclosed

        We Sell & Service All Major Brands